MTP-8 to MTP-8 UPC Trunk Cable, Female, 96 Fibers, OM4, Type B

MTP-8 to MTP-8 UPC Trunk Cable, Female, 96 Fibers, OM4, Type B

Pre-terminated MTP® Elite Female backbone trunk with 96 Fibers (Base-8) on OM4 50/125μm fiber. Instead of splicing dozens of connectors on site, your installers pull one cable, mount the panels and plug in.

Standard lengths are 1m (3ft), 3m (10ft), 5m (16ft), 7m (23ft), 10m (33ft), 15m (49ft), 20m (66ft), 25m (82ft), 30m (98ft) and 40m (131ft). Because we are the manufacturer, any other length between or beyond these steps can be produced on request, with your choice of jacket color, labeling and packaging.

Product Highlights

  • MTP® Elite Female (Non-Pinned) to MTP® Elite Female (Non-Pinned), 96 Fibers (Base-8)
  • OM4 50/125μm, bend insensitive fiber
  • Insertion loss ≤0.20dB, return loss ≥27dB
  • Type B polarity
  • 9.0mm Plenum (OFNP) round cable
  • Minimum bend radius 7.5mm
  • Ten standard lengths from 1m (3ft) to 40m (131ft), custom lengths built to order

Specifications

Part Number96FMTPOM4
ManufacturerHT
Connector AUS Conec MTP® Elite Female (Non-Pinned)
Connector BUS Conec MTP® Elite Female (Non-Pinned)
Fiber ModeOM4 50/125μm
Wavelength850/1300nm
Polish TypeUPC to UPC
PolarityType B
Cable JacketPlenum (OFNP)
Fiber Count96 Fibers (Base-8)
Glass FiberBend Insensitive Fiber
Cable StructureDouble Jacket
Minimum Bend Radius7.5mm
Cable Outside Diameter (OD)9.0mm
Breakout Outside Diameter (OD)2.0mm
Breakout Length0.84m
Long-term Tensile Load200N
Short-term Tensile Load660N
Insertion Loss≤0.20dB
Return Loss≥27dB
Attenuation at 850nm≤2.3dB/km
Attenuation at 1300nm≤0.6dB/km
Operating Temperature-10 to 60°C (14 to 140℉)
Storage Temperature-10 to 70°C (14 to 158℉)

Applications

Typical uses include backbone links between the main distribution area and equipment rows, vertical risers between floors, and inter-cabinet trunks in large data halls. The 96 Fibers (Base-8) construction concentrates the equivalent of many duplex jumpers into a single assembly, which is exactly what high density spine and leaf cabling needs. Pre-termination cuts installation time dramatically compared with field splicing.

Trunk Construction and Polarity

The trunk uses a double jacket design: a rugged outer sheath protects the whole bundle, while each breakout leg keeps its own jacket and numbering. Base-8 and Base-12 constructions are available depending on the fiber count. Polarity follows the Type shown in the table, and pulling eyes or mesh grips can be fitted for installation.

Ordering Information

Please reference 96FMTPOM4 in your enquiry. The 1m (3ft) version is the standard model; Our sales team can also advise on polarity, gender and jacket choices if your project documentation is not final yet.

Quality and Testing

We do not ship untested product. Each unit is measured on calibrated equipment for optical performance and visually inspected for end face quality before packing. Batch traceability is maintained so any field issue can be tracked back to production.

How We Pack

Products are packed in anti-static or PE bags with connector dust caps fitted, then boxed in sturdy export cartons. Custom labels, barcodes and carton markings are available on request.

Built to Your Spec

Our engineering team handles custom MPO/MTP assemblies daily. If the standard configuration does not match your link design, send us the requirement and we will build exactly what your network needs at factory-direct cost.




Home

Share on:



Wordwide perspectives

We have representatives in different places of the world.

  • Asia
  • America
  • Africa