Customized Duplex Uniboot Fiber Patch Cable, LC UPC, OS2

Customized Duplex Uniboot Fiber Patch Cable, LC UPC, OS2

Kenyan network installers should begin with the actual mating interfaces and site fiber records before assigning this product to a link. This project-specific fiber patch cable is built to the specific arrangement the project specifies: connector styles, polish, fiber mode, jacket and length are all specified at order time and the cable assembly is factory terminated and optically tested before dispatch.

Product Highlights

  • Offered in Riser (OFNR)/LSZH Flame-retardant Jacket with 1.6/2.0mm Cable Diameters
  • Available in Standard/Flat Clip and Push Pull Tabs Connector Types
  • Uniboot Design Allows One Cable to Carry Two Fibers to Reduce the Cable Bulk When Routing
  • Optical Performance Test for Normal Network Connections
  • Compliant to ANSI/TIA-568-D.3

Specifications

Fiber ModeOS2 9/125μm
Wavelength1310/1550nm
Fiber CountDuplex
Fiber GradeG.657.A1
Insertion LossUPC≤0.2dB
Return LossUPC≥50dB
Attenuation at 1310 nm≤0.4dB/km
Attenuation at 1550 nm≤0.3dB/km
Cable Outside Diameter (OD)1.6/2.0mm
Jacket ColorYellow
PolarityA (Tx) to B (Rx)
Operating Temperature-10 to 60°C (14 to 140°F)

Built to the order

The project-specific program covers the combinations that stock lists cannot: mixed connector families, non-standard jackets, unusual lengths, marking and packaging to the project specification. The cable assembly is terminated and tested exactly like a stock product, with the arrangement confirmed before manufacturing.

Bend tolerance in real cabinets

Patch fields are rarely kind to fiber. Leads pathway through tight managers, sharp tray corners and crowded vertical channels. The bend-insensitive glass in this cable assembly tolerates a 10mm fiber bend radius; therefore, a hurried routing decision during a night upkeep window will not turn into a measurable penalty on the channel.

Where single-mode jumpers earn their place

Single-mode patching carries the links that leave the room: campus backbones, carrier handoffs, long runs between buildings and every wavelength-multiplexed service. Because the OS2 glass in this cable assembly is the matching class used in the outside plant, the jumper cable will not become the weak point of the loss calculation. At 1310 and 1550nm the attenuation stays a fraction of a decibel per kilometer, and the optical connector pair adds less than 0.3dB when the end faces are clean and seated.

Length Options

Regular lengths cover the common patching routes: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), 10m (33ft), 15m (49ft), 20m (66ft), 30m (98ft), with project-specific length obtainable beyond the list. Specifying the measured pathway length keeps the slack out of the manager and the strain off the optical connectors.

Quality Control and Testing

Every assembly is terminated with precision zirconia ferrule connectors and optically tested before packing: insertion loss and return loss are verified on each cable, and end-face geometry is inspected for consistent physical contact. The optical cable ships with dust caps on both connectors and the test result obtainable on ask for.

Ordering and Factory Support

Refer to this arrangement by connector pair, fiber mode and length when asking for a quotation. For configurations outside the listed options, mixed connector families, jackets, marking or project packaging, send the specification with the request and the factory will check the build before manufacturing. Project support for Kenya and East Africa is available to reconcile the ordered configuration with the intended installation.




Home

Share on:



Wordwide perspectives

We have representatives in different places of the world.

  • Asia
  • America
  • Africa