LC UPC to Unterminated Fiber Pigtail, Simplex, OS2, 0.9mm

LC UPC to Unterminated Fiber Pigtail, Simplex, OS2, 0.9mm

Kenyan network installers should begin with the actual mating interfaces and site fiber records before assigning this product to a link. This fiber pigtail terminates outside-plant or backbone cable into a connectorized panel: LC UPC to Unterminated Fiber Pigtail, OS2 glass, with a factory-polished LC UPC connector on one end and a prepared fiber strand on the other. Fusion-spliced onto the incoming cable, it turns a raw fiber pathway into a documented, testable port.

Product Highlights

  • Precision Zirconia Ferrule Connectors Ensure Low Loss
  • Easy-strip 900µm Tight-buffered Coating
  • Color-Coded Cable Jacket for Easy Identification
  • Support Both Fusion and Mechanical Splicing
  • G.657.A1 Bend Insensitive Fiber & 10mm Min. Bend Radius

Specifications

Connector ALC UPC Simplex
Connector BUnterminated
Fiber Count1 Fiber
Fiber GradeG.657.A1
Fiber ModeOS2 9/125μm
Wavelength1310/1550nm
Jacket ColorYellow
Cable JacketPVC (Unrated)
Min. Bend Radius (Optical Fiber)10mm
Min. Bend Radius (Fiber Cable)10/5D (Dynamic/Static)
Connector Durability1000 Times
Attenuation at 1310nm0.36dB/km
Attenuation at 1550nm0.22dB/km
Insertion Loss≤0.3dB
Return Loss≥50dB
Operating Temperature-40 to 75°C (-40 to 167℉)
Storage Temperature-45 to 85°C (-49 to 185℉)
Connector TypeLC to Unterminated
Fiber Count1 Fiber
Fiber GradeG.657.A1

Why pigtails remain the standard termination

A pigtail is half a link: one end is a pre-terminated connector, polished and tested under method control; the other is a bare fiber strand ready for the splice. Fusion-splicing that strand onto the deployed cable brings the optical connector quality of the factory to a field pathway. The result outperforms field-polished connectors on insertion loss, return loss and long-term stability, and it outperforms pre-terminated trunks when the pathway length is uncertain or the pathway is difficult to pre-measure.

Fusion splicing practice that protects the budget

A good splice starts long before the splicer arcs: strip the strand cleanly, cleave square, keep the sleeve staged, and protect the completed splice in the tray with the bend radius respected. The tight-buffered 0.9mm coating on this pigtail strips in one motion and seats cleanly in standard splice sleeves. Done well, a fusion splice adds less attenuation than a connector pair and stays stable for the life of the plant. Kenyan installers can add this check to the handover record for future maintenance and fault tracing.

Mechanical splicing as the field fallback

Where a fusion splicer is never obtainable, mechanical splices get the channel up: the strand cleaves, seats in the mechanical splice body and locks against the field fiber. Because the loss is higher than a fusion joint and the reflectance worse, the practice is a fallback rather than a standard - but for urgent restoration work a pigtail that supports both methods keeps the version open.

Choosing the fiber mode for the plant

Single-mode OS2 serves long links, PON access and any plant where distance or wavelength plans matter; the bend-insensitive glass grade keeps attenuation stable in dense trays. OM3 and OM4 multimode serve equipment rooms and data halls where transceiver cost favors short-reach optics. OM1 and OM2 remain in service in legacy plants and must be matched like-for-like. The pigtail mode must equal the optical cable plant mode - a mismatch splices poorly and performs worse.

Bend-insensitive glass in dense trays

Splice trays and panel rear spaces punish fiber: tight routing, crowded dressing and the occasional hurried re-entry all bend strands beyond what legacy single-mode tolerated. The bend-insensitive grade used in this pigtail holds attenuation stable at bend radii that would fog conventional glass, which keeps the channel margin intact after the tenth tray opening, not just at commissioning.

A splicing workflow that scales

Productive termination crews work to a fixed routine: mount the tray, dress the optical cable, splice the pigtails color by color, protect each joint, test each completed port, then close and label. With the routine fixed, a two-person crew terminates a full frame slot in a predictable time, and the test record maps cleanly onto the documentation. The consistency further makes quality auditable - matching materials, matching sequence, matching pass criteria across every site.

Sparing and kit planning for termination work

Pigtails belong in the termination kit in counted sets with spares: strands break, connectors get contaminated beyond recovery, and a missing spare converts a ten-minute task into a second visit. Plan one spare set per frame slot, keep spare strands capped and bagged, and record which set went into which tray so replacement stock can usually be ordered to the identical specification.

Selecting the right pigtail for the job

Five decisions define the order: the optical connector range must match the adapter panel, the polish must match the plant, the fiber mode must match the optical cable, the structure must match the pathway, and the count must match the tray capacity. Getting all five right at order time is what turns a box of strands into a dependable termination. Where the specification sits outside the standard configurations, the project-specific platforms cover the remaining combinations.

Factory Testing and Quality Checks

Every pigtail is optically tested before packing: insertion loss and return loss are verified on each terminated leg, and the ferrule end faces are inspected for scratches and contamination. The strands ship coiled, capped and bagged, with the test results obtainable on ask for.

How to Order and Factory Support

Refer to this pigtail by connector, polish, fiber mode, fiber count and structure when asking for a quotation. For configurations outside the listed options - mixed connector families, jacket ratings, lengths or project packaging - send the specification with the request and the factory will check the manufacturable specification. Project support for Kenya and East Africa is available to reconcile the ordered configuration with the intended installation.