Kenyan network installers should begin with the actual mating interfaces and site fiber records before assigning this product to a link. This OM4 fiber patch cable carries a LC UPC interface on one end and a SC UPC interface on the other, factory terminated on OM4 glass and optically tested as a full product. The duplex zipcord structure keeps the transmit and receive strands paired in one product for fast, error-free patching.
Product Highlights
- Bend Insensitive Fiber with 7.5mm Min. Bend Radius
- Precision Zirconia Ferrule Connectors Ensure Low Loss
- Flame-Retardant Riser (OFNR) for Vertical and Floor-to-Floor Installations
- Color-Coded Cable Jacket for Easy Identification
- Duplex Zipcord Construction Reduces Risk of Damage from Crimping
Specifications
| Connector A | LC UPC Duplex |
|---|---|
| Connector B | SC UPC Duplex |
| Fiber Count | 2 Fibers |
| Fiber Grade | Bend Insensitive Fiber |
| Fiber Mode | OM4 50/125μm |
| Wavelength | 850/1300nm |
| Flame Rating | Riser (OFNR) |
| Cable Outside Diameter (OD) | 2.0mm |
| Polarity | A (Tx) to B (Rx) |
| Cable Type | Tight-Buffered |
| Min. Bend Radius (Optical Fiber) | 7.5mm |
| Min. Bend Radius (Fiber Cable) | 20/10D (Dynamic/Static) |
| Connector Durability | 1000 times |
| Tensile Strength | 90/150N (Long/Short Term) |
| Insertion Loss | ≤0.3dB |
| Return Loss | ≥30dB |
| Attenuation at 850nm | ≤3.5dB/km |
| Attenuation at 1300nm | ≤1.5dB/km |
| Operating Temperature | -10 to 70°C (14 to 158℉) |
| Storage Temperature | -20 to 70°C (-4 to 158℉) |
Polarity and pairing in duplex links
A duplex jumper is two fibers with a defined A-to-B crossover. Getting polarity right at the cord level keeps the path consistent end to end, which is why these assemblies are built and tested as a pair rather than as two distinct strands.
Multimode reach for the data hall
This OM4 product serves the short-reach fabric of the data center: 10G and 25G server uplinks, 40G and 100G SR4 spine links and the inter-row runs between them. On OM4 glass, 10G Ethernet holds to 400 meters and 100G SR4 to 100 meters, which covers the overwhelming majority of in-hall routes with margin to spare.
Length Options
Regular lengths cover the common patching routes: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), 7m (23ft), 10m (33ft), 15m (49ft), with project-specific length obtainable beyond the list. Specifying the measured pathway length keeps the slack out of the manager and the strain off the optical connectors.
Quality Control and Testing
Every assembly is terminated with precision zirconia ferrule connectors and optically tested before packing: insertion loss and return loss are verified on each cable, and end-face geometry is inspected for consistent physical contact. The optical cable ships with dust caps on both connectors and the test result obtainable on ask for.
Ordering and Factory Support
Refer to this arrangement by connector pair, fiber mode and length when asking for a quotation. For configurations outside the listed options, mixed connector families, jackets, marking or project packaging, send the specification with the request and the factory will check the build before manufacturing. Project support for Kenya and East Africa is available to reconcile the ordered configuration with the intended installation.