OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-DAC-1.5M5FT 800G OSFP 8 x 100G PAM4 IHS/Finned Top to 2 x 400G OSFP 4 x 100G PAM4 RHS/Flat Top Passive Copper Breakout Cable, 1.5m (5ft)

OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-DAC-1.5M5FT 800G OSFP 8 x 100G PAM4 IHS/Finned Top to 2 x 400G OSFP 4 x 100G PAM4 RHS/Flat Top Passive Copper Breakout Cable, 1.5m (5ft)

For buyers working from an equipment parts list, OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-DAC-1.5M5FT identifies more than a connector style. It refers here to a 1.5m (5ft) DAC cable for Generic hosts, supporting 800G operation with OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top). The sections below separate the OEM cross-reference, physical specification and HT factory checks for straightforward purchasing review.

OEM Part Number: OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-DAC-1.5M5FTHT Part Number: OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-DAC-1.5M5FT

Product Highlights

  • HT-manufactured DAC assembly in 1.5m (5ft)
  • 800G connectivity at 800Gbps
  • Interface configuration: OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)
  • Fixed length and part number: 1.5m (5ft), OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-DAC-1.5M5FT
  • Cable construction: Passive Breakout DAC
  • Conductor specification: 26AWG
  • Maximum power consumption: 0.1W (800G End)0.1W (400G Per End)
  • Minimum bend radius: 72mm

Specifications

HT Part NumberOSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-DAC-1.5M5FT
ManufacturerHT
Form FactorOSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)
Max. Data Rate800Gbps
MediaCopper
Cable TypePassive Breakout DAC
Cable Length1.5m (5ft)
Jacket MaterialPET
Minimum Bend Radius72mm
Wire AWG26AWG
Max. Power Consumption0.1W (800G End)0.1W (400G Per End)
Modulation Format8x 100G-PAM4 to Dual 4x 100G-PAM4
Commercial Temperature Range0 to 70°C (32 to 158°F)
Application800G/400G Ethernet
ProtocolsOSFP MSA Rev5.0, IEEE 802.3ck, CMIS 4.0

Signal and Lane Configuration

The listed modulation format is 8x 100G-PAM4 to Dual 4x 100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Network and Protocol Considerations

The intended application is 800G/400G Ethernet. Listed interface and protocol references include OSFP MSA Rev5.0, IEEE 802.3ck, CMIS 4.0. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top) configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

The additional half metre beyond a one-metre assembly gives OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-DAC-1.5M5FT useful routing flexibility when the ports are not directly aligned. It can accommodate a different rack unit or a short service loop, but excess cable should be dressed loosely rather than folded into a tight coil.

Position Within the Length Range

OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-DAC-1.5M5FT occupies the middle of this family between OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-DAC-1M3FT at 1m (3ft) and OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-DAC-2M7FT at 2m (7ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Procurement and Port-Mapping Review

A useful purchase order should identify the host platform, the expected OEM code and the exact cable length as separate pieces of information. This prevents a physically similar assembly from being substituted when the port identification or reach is different. For mixed-length installations, prepare one order line per part number and reconcile each delivered cable with its intended pair of ports. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 72mm; the stated power consumption is 0.1W (800G End)0.1W (400G Per End); the jacket material is PET.

Power and Thermal Planning

The rated power consumption is 0.1W (800G End)0.1W (400G Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 26AWG conductors, PET jacket, minimum bend radius 72mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Generic Compatibility and Factory Testing

Our procurement-oriented compatibility check begins with the OEM reference and ends with a live host link. We record the physical length separately from the identification configuration, so the cable supplied for this page remains the stated version rather than a generic length substitute. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Ordering Information

For a clear bill of materials, quote the OEM reference, HT part number, length and quantity on the same line. Add the switch or server model and software release when a pre-order review is required; project labels can repeat those details for receiving and installation teams. This page’s fixed configuration is 1.5m (5ft); another length must be quoted under its corresponding part number.

Quality Assurance and Packaging

Before packing, the assembly is checked for connector condition, identification and link operation. Cables for multi-line orders can be labelled and grouped by part number, making it easier to match each length to the procurement record without opening every protective bag. Volume orders can include customer references on the labels and carton list.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.




Home