SC UPC Simplex Armored Fiber Patch Cable, OS2, Riser (OFCR)

SC UPC Simplex Armored Fiber Patch Cable, OS2, Riser (OFCR)

Kenyan network installers should begin with the actual mating interfaces and site fiber records before assigning this product to a link. This simplex armored patch cable runs one OS2 9/125µm single-mode fiber between two SC UPC connectors, wrapped in a helical stainless steel tube under the blue 3.0mm riser-rated (OFCR) jacket. It suits the long tail of equipment that still speaks SC UPC: media converters, legacy ODFs, industrial switches and test sets that now sit at the exposed edge of the network. Kenyan installers can add this check to the handover record for future maintenance and fault tracing.

Product Highlights

  • Helical stainless steel armor against crush, impact and rodents
  • G.657.A1 bend-insensitive fiber, 10/5D bend radius
  • Riser (OFCR) flame rating for vertical building pathways
  • Insertion loss ≤0.3dB, return loss ≥50dB
  • Stock lengths 1m to 30m; custom lengths and jackets on request
  • SC UPC to SC UPC simplex, OS2 9/125µm single mode

Specifications

Connector TypeSC to SC
Polish TypeUPC to UPC
Fiber ModeOS2 9/125µm
Wavelength1310/1550nm
Fiber CountSimplex
Fiber GradeG.657.A1 (Compatible with G.652.D)
Min. Bend Radius (Fiber Cable)10/5D (Dynamic/Static)
Cable Outside Diameter (OD)3.0mm
Flame RatingRiser (OFCR)
Construction TypeSingle Armored, Stainless Steel Tube
Tensile Strength120/225N (Long/Short Term)
Insertion Loss≤0.3dB
Return Loss≥50dB
Operating Temperature-20 to 70°C (-4 to 158°F)
Storage Temperature-40 to 70°C (-40 to 158°F)

Simplex SC for BiDi optics and single-fiber links

Bidirectional transceivers put both directions on one strand, and a simplex SC cord is the natural patching format for them. The matching build serves WDM monitor ports, optical taps and any channel where only one fiber is lit. Patching with a single-fiber cord keeps the unused side of the frame free and makes the strand easy to trace months later.

Where SC UPC remains the standard

Media converters, older carrier CPE, industrial Ethernet switches and much deployed ODF hardware still present SC UPC ports. The push-pull SC body is tolerant of frequent handling and easy to clean and check, which keeps it in service long after LC took over the transceiver side. This cord lets that plant stay exactly as documented while gaining armored protection.

Armor under the floor and behind the wall

Simplex tails commonly disappear into places nobody inspects again: beneath raised floors, behind wall boxes, along baseboards in retrofit offices. Those are precisely the routes where unarmored leads get crushed or chewed. The helical steel tube inside this cord carries the mechanical rating; therefore, the pathway needs no conduit and the channel survives the life of the building.

Media converters and industrial links

A large share of simplex SC UPC demand comes from media converters and industrial Ethernet gear linking control rooms to field cabinets. Because these links run for years in cabinets that get opened monthly, the cord is handled far more than a data-center jumper. The armored build and the 1000-cycle ferrule rating are aimed at exactly that service pattern, and the stock lengths cover the usual cabinet-to-frame distances.

Standard lengths and custom builds

Regular lengths are stocked for fast delivery: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), 10m (33ft), 15m (49ft), 20m (66ft) and 30m (98ft), covering the common rack-to-rack, access and frame connections this cord is built for. Project-specific lengths beyond this range are manufactured to order. Because simplex tails are frequently dressed into tight enclosures, ordering the measured length avoids the coil of slack that otherwise ends up trapped behind the adapter panel. Specifying the specific pathway length avoids both the slack storage problem of an overlong cord and the strain risk of one that is too short.

Factory testing and quality checks

Every cord is terminated with precision zirconia ferrule SC connectors and verified for insertion loss and return loss before packing; the 0.3dB and 50dB figures are tested ratings on each product. End-face geometry is inspected for reproducible physical contact, and the ferrules are rated for up to one thousand mating cycles.

How to Order and Factory Support

Refer to the SC UPC simplex armored range when asking for a quotation, stating the pathway length and jacket rating. Other connector mixes and polish types, including hybrid builds, are handled through the project-specific simplex armored program once the factory confirms the specification. Project support for Kenya and East Africa is available to reconcile the ordered configuration with the intended installation.