SFP28 to SFP28-25G-DAC-2.5M8FT 25G SFP28 Passive Copper Twinax Cable, 2.5m (8ft)

For buyers working from an equipment parts list, SFP28 to SFP28-25G-DAC-2.5M8FT identifies more than a connector style. It refers here to a 2.5m (8ft) DAC cable for Generic hosts, supporting 25G operation with SFP28 to SFP28. The sections below separate the OEM cross-reference, physical specification and HT factory checks for straightforward purchasing review.
OEM Part Number: SFP28 to SFP28-25G-DAC-2.5M8FTHT Part Number: SFP28 to SFP28-25G-DAC-2.5M8FT
Product Highlights
- HT-manufactured DAC assembly in 2.5m (8ft)
- 25G connectivity at 25Gbps
- Interface configuration: SFP28 to SFP28
- Fixed length and part number: 2.5m (8ft), SFP28 to SFP28-25G-DAC-2.5M8FT
- Conductor specification: 30AWG
- Minimum bend radius: 21.25mm
Specifications
| HT Part Number | SFP28 to SFP28-25G-DAC-2.5M8FT |
|---|---|
| Manufacturer | HT |
| Connector Type | SFP28 to SFP28 |
| Max Data Rate | 25Gbps |
| Minimum Bend Radius | 21.25mm |
| Wire AWG | 30AWG |
| Cable Length | 2.5m (8.2ft) |
| Jacket Material | PVC (OFNR) |
| Typical Power Consumption | ≤0.5W |
| Power Supply | 3.3V |
| Temperature | 0 to 70°C (32 to 158°F) |
| Protocols | IEEE 802.3, SFP28 MSA, SFF-8402, Infiniband, EIA 364-1000 |
| Application | 25G Ethernet, Data Center, 5G Wireless |
Cable Construction and Routing
This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 21.25mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Procurement and Port-Mapping Review
A useful purchase order should identify the host platform, the expected OEM code and the exact cable length as separate pieces of information. This prevents a physically similar assembly from being substituted when the port identification or reach is different. For mixed-length installations, prepare one order line per part number and reconcile each delivered cable with its intended pair of ports. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 21.25mm; the jacket material is PVC (OFNR).
Network and Protocol Considerations
The intended application is 25G Ethernet, Data Center, 5G Wireless. Listed interface and protocol references include IEEE 802.3, SFP28 MSA, SFF-8402, Infiniband, EIA 364-1000. Confirm that the host firmware and port configuration support the same operating mode.
Passive Copper Operation
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
Length Selection and Installation Planning
The 2.5m (8ft) version is useful when a two-metre run would leave insufficient working slack. Before installation, check the complete horizontal and vertical path so that SFP28 to SFP28-25G-DAC-2.5M8FT reaches both ports without tension at either connector.
Position Within the Length Range
SFP28 to SFP28-25G-DAC-2.5M8FT occupies the middle of this family between SFP28 to SFP28-25G-DAC-2M7FT at 2m (7ft) and SFP28 to SFP28-25G-DAC-3M10FT at 3m (10ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Generic Compatibility and Factory Testing
Our procurement-oriented compatibility check begins with the OEM reference and ends with a live host link. We record the physical length separately from the identification configuration, so the cable supplied for this page remains the stated version rather than a generic length substitute. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.
Ordering Information
For a clear bill of materials, quote the OEM reference, HT part number, length and quantity on the same line. Add the switch or server model and software release when a pre-order review is required; project labels can repeat those details for receiving and installation teams. Quantity and any labeling instructions should be attached specifically to SFP28 to SFP28-25G-DAC-2.5M8FT.
Quality Assurance and Packaging
Before packing, the assembly is checked for connector condition, identification and link operation. Cables for multi-line orders can be labelled and grouped by part number, making it easier to match each length to the procurement record without opening every protective bag. Standard protective packing is used by default, with project documentation arranged when requested.
Frequently Asked Questions
Is this an original equipment manufacturer cable?
No. It is manufactured by HT under our own manufacturer identity.
Can excess cable be folded into a compact bundle?
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Will any matching connector operate at the same speed?
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
What details assist a compatibility review?
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Shipping and Lead Time
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.