SFP56-50G-ACC-5M16FT 50G SFP56 Active Copper Twinax Cable, 5m (16ft)

SFP56-50G-ACC-5M16FT 50G SFP56 Active Copper Twinax Cable, 5m (16ft)

For buyers working from an equipment parts list, SFP56-50G-ACC-5M16FT identifies more than a connector style. It refers here to a 5m (16ft) ACC cable for Generic hosts, supporting 50G operation with SFP56. The sections below separate the OEM cross-reference, physical specification and HT factory checks for straightforward purchasing review.

OEM Part Number: SFP56-50G-ACC-5M16FTHT Part Number: SFP56-50G-ACC-5M16FT

Product Highlights

  • HT-manufactured ACC assembly in 5m (16ft)
  • 50G connectivity at 50Gbps
  • Interface configuration: SFP56
  • Fixed length and part number: 5m (16ft), SFP56-50G-ACC-5M16FT
  • Cable construction: Active Twinax
  • Conductor specification: 28AWG
  • Maximum power consumption: ≤0.5W
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberSFP56-50G-ACC-5M16FT
CompatibleGeneric
ManufacturerHT
Form FactorSFP56
Max Data Rate50Gbps
Cable TypeActive Twinax
Max Cable DistanceUp to 7m
Cable Length5m(16ft)
Wire AWG28AWG
Power Consumption≤0.5W
Jacket MaterialPVC
Storage Temperature-40 to 85°C (-40 to 185°F)
Operating Temperature0 to 70°C (32 to 158°F)
Modulation TechnologyPAM4
Bit Rate53.125 Gbps
ProtocolSFP56 MSA

Power and Thermal Planning

The rated power consumption is ≤0.5W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Position Within the Length Range

SFP56-50G-ACC-5M16FT occupies the middle of this family between SFP56-50G-ACC-3M10FT at 3m (10ft) and SFP56-50G-ACC-7M23FT at 7m (23ft). It adds 2m over the shorter option for extra routing clearance, while the next longer version adds another 2m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Procurement and Port-Mapping Review

A useful purchase order should identify the host platform, the expected OEM code and the exact cable length as separate pieces of information. This prevents a physically similar assembly from being substituted when the port identification or reach is different. For mixed-length installations, prepare one order line per part number and reconcile each delivered cable with its intended pair of ports. For this assembly, the listed conductor specification is 28AWG; the stated power consumption is ≤0.5W; the jacket material is PVC.

Cable Construction and Routing

This assembly uses 28AWG conductors, PVC jacket. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Length Selection and Installation Planning

The 5m (16ft) length gives SFP56-50G-ACC-5M16FT more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the ACC specification and host support must still match the intended link.

Generic Compatibility and Factory Testing

Our procurement-oriented compatibility check begins with the OEM reference and ends with a live host link. We record the physical length separately from the identification configuration, so the cable supplied for this page remains the stated version rather than a generic length substitute. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Ordering Information

For a clear bill of materials, quote the OEM reference, HT part number, length and quantity on the same line. Add the switch or server model and software release when a pre-order review is required; project labels can repeat those details for receiving and installation teams. Quantity and any labeling instructions should be attached specifically to SFP56-50G-ACC-5M16FT.

Quality Assurance and Packaging

Before packing, the assembly is checked for connector condition, identification and link operation. Cables for multi-line orders can be labelled and grouped by part number, making it easier to match each length to the procurement record without opening every protective bag. Standard protective packing is used by default, with project documentation arranged when requested.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Does this order code cover multiple lengths?

No. SFP56-50G-ACC-5M16FT refers here to 5m (16ft). Every other verified length has a separate part number and page in the length list.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.




Home

Share on:



Wordwide perspectives

We have representatives in different places of the world.

  • Asia
  • America
  • Africa