SC to SC Duplex Armored Fiber Patch Cable, OM4, Riser (OFCR)

SC to SC Duplex Armored Fiber Patch Cable, OM4, Riser (OFCR)

Kenyan network installers should begin with the actual mating interfaces and site fiber records before assigning this product to a link. This duplex armored patch cable fits SC UPC connectors on both connector ends of an OM4 50/125µm multimode product, with a helical stainless steel tube protecting the fibers under the aqua 3.0mm riser-rated (OFCR) jacket. It is built for installations where SC interfaces remain on the panels and hardware but the pathway demands real mechanical protection: open ceilings, industrial floors and shared risers.

Product Highlights

  • Helical stainless steel armor against crush, impact and rodents
  • Bend-insensitive OM4 fiber, 20/10D dynamic/static bend radius
  • Riser (OFCR) flame rating for vertical building pathways
  • Insertion loss ≤0.3dB, return loss ≥20dB
  • Stock lengths 1m to 30m; custom lengths and jackets on request
  • SC UPC to SC UPC duplex, OM4 50/125µm multimode

Specifications

Connector TypeSC to SC
Polish TypeUPC to UPC
Fiber ModeOM4 50/125µm
Wavelength850/1300nm
Fiber CountDuplex
Fiber GradeOM4 Bend Insensitive
Min. Bend Radius (Fiber Cable)20/10D (Dynamic/Static)
Cable Outside Diameter (OD)3.0mm
Flame RatingRiser (OFCR)
Construction TypeSingle Armored, Stainless Steel Tube
Tensile Strength120/225N (Long/Short Term)
Insertion Loss≤0.3dB
Return Loss≥20dB
Operating Temperature-20 to 70°C (-4 to 158°F)
Storage Temperature-40 to 70°C (-40 to 158°F)

SC duplex interfaces in panel and legacy environments

SC connectors remain common on wall-mounted enclosures, older fiber distribution frames, media converters and industrial Ethernet gear. The push-pull latching body tolerates frequent handling and is easy to seat with gloved hands, which is part of why SC persists in field-side cabling. This cord keeps that familiar interface while adding the steel armor those exposed environments generally demand.

OM4 bandwidth for short-reach optics

Behind the SC bodies the glass is full OM4: 10GBASE-SR to 400m, with headroom for 40G and 100G short-reach optics at row and room distances. For buildings that standardized on SC panels years ago, this makes it possible to upgrade channel speeds without re-terminating the fixed plant, as long as the path stays within the OM4 distance envelope.

Steel armor for exposed routing

SC-terminated links are commonly found exactly where cables get hurt: factory floors, campus outbuildings, temporary runs at events and structure sites. Because the helical stainless tube inside the jacket wraps the buffered fibers directly, the cord shrugs off crushing under floor tiles, accidental pulls and rodent damage. Field staff can cross areas that would otherwise call for conduit, keeping the pathway small and easy to change later.

Care of SC connectors in the field

SC ferrules are 2.5mm and easy to check with standard tips and microscopes. clean both end faces with a dry cassette cleaner and check if the channel margin is tight; most "bad cord" reports in the field trace back to contamination rather than damage prior to mating. The push-pull housing should click positively; if it will not, verify for dust caps left in the mating adapter rather than forcing the latch.

Standard lengths and custom builds

Regular lengths are stocked for fast delivery: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), 10m (33ft), 15m (49ft), 20m (66ft) and 30m (98ft), covering the common rack-to-rack, access and frame connections this cord is built for. Project-specific lengths beyond this range are manufactured to order. Matching the cord length to the actual pathway keeps slack out of the adapter panel and preserves the 850nm channel budget on longer multimode runs. Specifying the specific pathway length avoids both the slack storage problem of an overlong cord and the strain risk of one that is too short.

Factory testing and quality checks

Each SC-terminated product is built with precision zirconia ferrules and tested for insertion loss and return loss before packing; the 0.3dB ceiling is verified on every cord. End-face geometry is checked for stable physical contact across repeat matings, and the SC housings are latch-tested for positive engagement.

How to Order and Factory Support

Use against the SC-SC OM4 duplex armored range with the pathway length and jacket rating stated. Other connector mixes, polish types and jacket colors are obtainable through the project-specific duplex armored program once the factory confirms the requested specification. Project support for Kenya and East Africa is available to reconcile the ordered configuration with the intended installation.